WEBINAR - Half Day Webinar on Risk Analysis and External Lightning Protection - Session 1
Venue: Digital Platform
Date & Time: 06 Aug 2020 (9:00 AM - 1:00 PM) Closed
CPD: 4
Closing Date Before: 03-Aug-2020 (Subject to change based on availability of seat)
Organised By Technical Division - Electrical Engineering (EETD)

SYNOPSIS

Did you know that Malaysia has adopted the MS IEC 62035 Part 1 to 4 Protection Against Lightning since 2006 while Britain replaced BS6651 with BS E N 62035 from 1st September 2008. What are the main differences between BS6651 and MS IEC 62035? we will also explore about External Lighting Protection MS IEC 62035 Part 3:

1. Three components of External Lightning Protection: Air Termination, Down Conductors and Earthing
2. Rolling Sphere Protection angle and mesh size according to LPS I, II, III or IV
3. Placement of Air Termination Rod based on Rolling Sphere
4. Definition and use of Separation Distance 'S'
5. Spacing between down conductors according to LPS I, II, III or IV
6. Use of Reinforcement bars as down conductors
7. Welded Joints v/s clamped Joints v/s Bound joints v/s latched joints
8. Types of Earthing; Type A or Type B
9. Equipotential Earthing


BIODATA OF SPEAKER
Mr. RITESH LUTCHMAN


Mr Ritesh Lutchman is currently the Senior Sales and Marketing Manager at Wisepro Sdn Bhd. He has been working in the industry for the past 15 years and has gathered great experience in the design, installation, troubleshooting and site works for the industries mentioned above. He has also received extensive training on the Lightning Protection at Dehn headquarters in Germany, power factor capacitors, reactors and harmonics at Shizuki headquarters in Japan and ATS applications and troubleshooting at Vitzrotech headquarters in Korea. He graduated from the University of Cape Town with a degree in Electrical Engineering in 2004 and Master’s Degree in Electrical Engineering in 2006.



Limited to 470 participants only (first come basis) and invitation email will be sent for successful registration latest by 05 August 2020 @ 5.00 PM


Additional Information
Posted on
 
 
WEBINAR - Risk Analysis and External Lightning Protection - Session 1
Flyer

14-Jul-2020
Download
Post Comment
 
Member Type Normal Rate
(RM)
Online Rate
(RM)
DISTINGUISHED HONORARY FELLOW 80.00 80.00
HONORARY FELLOW 80.00 80.00
FELLOW 80.00 80.00
DISTINGUISHED MEMBER 80.00 80.00
SENIOR MEMBER 80.00 80.00
MEMBER 80.00 80.00
HONORARY MEMBER 80.00 80.00
SENIOR GRADUATE 80.00 80.00
GRADUATE 80.00 80.00
INCORPORATED MEMBER 80.00 80.00
AFFILIATE 80.00 80.00
ASSOCIATE MEMBER 80.00 80.00
STUDENT 80.00 80.00
Non IEM Member 160.00 160.00

For IEM members, please CLICK HERE to login for member rate
Rate stated does not include 8% SST
Non IEM Member will be charged an additional RM 20.00 Admin Fees inclusive 8% SST.




Advertisement


Advertisement

Advertisement

Advertisement
Survey Form


NEWSLETTER

Sign up for our newsletter to receive more information
Name:

Email Address:

Follow Us